Chapter · 1991

Environmental Monitoring of the Paphos Mosaics

N. Agnew and Po-Ming Lin; edited by N. Stanley Price

In The Conservation of the Orpheus Mosaic at Paphos, Cyprus, 42-45. The Getty Conservation Institute

A chapter on the monitoring of temperature, relative humidity and groundwater at the Paphos mosaics, and on what the readings show about the shelters built over them.

Agnew and Lin start from the hazards to the Paphos mosaics: seasonal wetting and drying, plant growth, wind and salt spray. Four portable temperature and relative-humidity recorders went in during September 1988, but dust and insect infestation made their results intermittent and the humidity sensors needed frequent calibration. Department of Antiquities staff added readings taken at about 7:30 A.M. and 1:30 P.M. at locations including the Aion, Achilles, Hercules and Amazon, and Orpheus mosaics.

Spot measurements from August 1989 through May 1990 show similar temperature and humidity at sheltered and exposed sites, and the authors judge the seasonal and daily ranges not to be major contributors to deterioration. The hazards they identify are direct wetting followed by drying, plant growth and moisture carrying salts. They argue that side walls or panels on the shelters can reduce wetting by rain while allowing air to move, and suggest that the lack of air movement explains the summer discomfort visitors report in the enclosed Aion structure (p. 43).

Groundwater at Paphos is high in chloride and lies close to sea level, and the authors discuss salt spray and the possible part played by salt crystallization in the mosaics' deterioration, noting that rain may flush exposed mosaics (p. 44).

What it records

  • The fifty-year average rainfall (1908–1957) of the Paphos area ranges from 400 mm on the coastal plain to 600 mm further inland.p. 42
  • Four portable Shinyei THR-2 temperature and relative-humidity recorders were installed in wooden cases in September 1988.p. 42
  • The representative hand-held measurements cover August 1989 through May 1990.p. 43
  • Relative humidity varied from 80% to 48% and temperature from 33 to 10 °C over the seasonal and daily cycles, ranges Agnew and Lin do not consider excessive.p. 43
  • Temperature in the Aion structure was no higher than in the more open shelters.p. 43
  • Groundwater chloride in the Paphos area ranges from 100 to 3000 ppm.p. 44
  • The water table at Paphos stands 0.18 metres above sea level.p. 44

Where to read

  • Recorder problems and monitoring locationspp. 42–43
  • Temperature and relative-humidity results and shelter comparisonsp. 43
  • Groundwater, salt spray and salt crystallizationp. 44

People, places and institutions

Institutions

  • Department of Antiquitiesstaff took spot measurements

Places

  • Paphoslocation of the monitored mosaics
  • Aion mosaicmonitored mosaic site
  • House of Aionprotective building erected in 1987
  • Hercules and Amazon mosaicmonitored mosaic site

Also named: Achilles mosaic, House of Theseus, House of Orpheus.

Extent pp. 42–45, Figs 43–44; bibliography

Landscape and ClimateArchitecture

Corrections and additions

Know this document?

Help us cite it fully and point readers to a copy.

We would like to hear about

  • The full citation, or a correction to ours
  • Where a copy can be read or downloaded
  • Missing parts, volumes or plates
  • Related documents

Tell us if you would like to be thanked by name on the page.